  • Display: 3.5-inch LCD
  • Display Resolution: 320*240
  • Input channel: 1~18
  • Input signal: (4~20)mA,(0~20)mA, (0~10)mA,RTD:PT100,Cu50, (1~5)V,(0~10)V,(0~5)V,TC:K, B,E,J,S,T,R,N,(0~20)mV, (-20~20)mV,(0~100)mV, RS485
  • Sampling Interval: 1s
  • Record Interval (chart speed): 1s~60min
  • Accuracy: 0.2%F.S
Enquire Now

SR-RPL800C Paperless recorder

  • Display: 7.0-inch LED
  • Display Resolution: 800*480
  • Input channel: 1~48
  • Input signal: (4~20)mA,(0~20)mA, (0~10)mA,RTD:PT100, Cu50,(1~5)V,(0~10)V, (0~5)V,TC: K,B,S,E,J,T,R, N,F2(0~20)mV,(-20~20)mV, (0~100)mV
  • Sampling Interval: 1s
  • Record Interval (chart speed): 1s~4min
  • Accuracy: 0.2%F.S
Enquire Now

 SR-RPL800F Paperless recorder

  • Display: 7.0-inch LED
  • Display Resolution: 800*480
  • Input channel: 1~36
  • Input signal: (4~20)mA,(0~20)mA, (0~10)mA,RTD:PT100,Cu50, (1~5)V,(0~10)V,(0~5)V,TC: K,B,S,E,J,T,R,N,F2(0~20)mV, (-20~20)mV,(0~100)mV
  • Sampling Interval: 1s
  • Record Interval (chart speed): 1s~60min
  • Accuracy: 0.2%F.S
Enquire Now

SR-RC900 Chart recorder

  • Display: OLED
  • Display Resolution: 128*64
  • Input channel: 1~8
  • Input signal: (4~20)mA,(0~10)mA, RTD:PT100,Cu50,(1~5)V, (0~10)V,(0~5)V,TC: K,B, E,J,S,T,R,N,(0~20)mV, (0~100)mV
  • Sampling Interval: 0.6s
  • Record Interval (chart speed): 10~2000mm/h
  • Accuracy: 0.2%F.S
Enquire Now

Liquid Analysis

SR-TUR300 Turbidity Controller

  • Display: 4.3-inch touch screen
  • Weight: 4.5Kg
  • Ingress protection: IP54
  • Display range: 0-1NTU | 0-20NTU | 0-100NTU | Optional
  • Accuracy: ±2% or ±0.015 NTU (Based on Formazin Primary Standard at 25°C)
  • Resolution: 0.0001 NTU
  • Zero point drift: ≤±0.015 NTU
Enquire Now

SR-MPC500 Multi-parameter Controller

  • Display: 7-inch touch screen
  • Weight: 30Kg
  • Ingress protection: IP54
  • Display range: Turbidity(0~1NTU / 0~20NTU / 0~100NTU / 0~4000NTU)
    Residual chlorine/Chlorine dioxide (0~5mg/L/0~20mg/L)
    Temperature(0~50 °C) PH / ORP(0~14pH, ±2000mV) (optional)
    Conductivity(0~2000uS/cm)(optional)
    Dissolved oxygen(0~20mg/L)(optional)
  • Power Supply: (220±22)VAC,(50±1)Hz
  • Operating temperature: 4 °C~+50 °C / -25 °C~+50 °C (optional temperature control heating antifreeze module)
  • Relative humidity: ≤95%RH(No condensation)
Enquire Now

SR-RCC400 Residual Chlorine Controller

  • Display: 7-inch touch screen
  • Weight: 8Kg
  • Ingress protection: IP43
  • Display range: Residual chlorine(0~5mg/L)
    Temperature(0.1~40.0 °C)
  • Resolution: 0.01
  • Power supply: (220±22)VAC,(50±1)Hz
  • Operating temperature: 0 °C~40 °C (No condensation)
  • Relative humidity: ≤95%(No condensation)
Enquire Now

SR-UC5000 Universal controller

  • Display: 2.8-inch LCD display
  • Range: pH(0~14pH)
    ORP(-2000~+2000mV)
    Dissolved oxygen(0~20mg/L /0~40mg/L)
    Saturation(0~200%)
    Conductivity (0~600mS/cm)
    Turbidity(0~4000NTU)
    SS/TSS (0~120000mg/L)
  • Relay output: One set of high and loW limit alarms (3A/250VAC),normally open contact relay
  • Communication: RS-485 communication, MODBUS RTU
  • Transmission: Isolated 4~20mA output, the maximum loop is 750Ω, ±0.2%F.S
  • Overall dimension: 100mm×100mm×150mm
Enquire Now

SR-PH6.0 pH controller

  • Display: 2.8-inch LCD display
  • Range: pH(0~14pH)
    ORP(-1000~+1000mV/ -2000~+2000mV)
  • Relay output: One set of high and loW limit alarms (3A/250VAC),normally open contact relay
  • Communication: RS-485 communication, MODBUS RTU
  • Transmission: Isolated 4~20mA output, the maximum loop is 750Ω, ±0.2%F.S
  • Overall dimension: 100mm×100mm×150mm
Enquire Now

SR-PH7.0 pH controller

  • Display: 4.3-inch TFT display
  • Range: pH(-2~16pH)
    ORP(-1999 ~ 1999mV)
  • Relay output: One set of high and loW limit alarms (3A/250VAC),normally open contact relay
  • Communication: RS-485 communication, MODBUS RTU
  • Transmission: Isolated 4~20mA output, the maximum loop is 750Ω, ±0.2%F.S
  • Overall dimension: 144mm×144mm×115mm
Enquire Now

SR-TDS200 Conductivity controller

  • Display: 2.8-inch LCD display
  • Range: 0.01electrode (0.20 ~ 200.0μS/cm)
    0.1electrode (2.00 ~ 2000μS/cm)
    1.0electrode (0.02 ~ 20.0mS/cm)
    10.0electrode (0.20 ~ 200.0mS/cm)
    Temperature(-10 ~130 °C)
  • Relay output: the relay load is 3A/ 250VAC
  • Communication: RS-485 communication, MODBUS RTU
  • Transmission: Isolated 4~20mA output, the maximum loop is 750Ω, ±0.2%F.S
  • Overall dimension: 100mm×100mm×150mm
Enquire Now

SR-PH-522 pH sensor parameter

  • Measuring range: 0~14pH
  • Temperature range: 0~135°C
  • (ORP) Zero electric potentia (pH, DS) Temperature compensation: Optional
  • Pressure resistance: ≤1.0Mpa
  • Thread: PG13.5mm
  • Body material: Glass
  • Application: Printing and dyeing electronics, paper making | Electroplating, desulphurisation
Enquire Now

SR-PH-602 pH sensor parameter

  • Measuring range: 0~14pH
  • Temperature range: 0~100°C
  • (ORP) Zero electric potentia (pH, DS) Temperature compensation: Optional
  • Pressure resistance: ≤0.6Mpa
  • Thread: PG13.5mm
  • Body material: Glass
  • Application:Industrial WasteWater With suspended matter in solution, such as aquaculture, mining
Enquire Now

SR-PH-515 pH sensor parameter

  • Measuring range: 0~14pH
  • Temperature range: 0~130°C
  • (ORP) Zero electric potentia (pH, DS) Temperature compensation: Optional
  • Pressure resistance: ≤0.25Mpa
  • Thread: PG13.5mm
  • Body material: Glass
  • Application: Mining and smelting, paper making, wastewater treatment
Enquire Now

SR-PH-550 pH sensor parameter

  • Measuring range: 0~14pH
  • Temperature range: 0~130°C
  • (ORP) Zero electric potentia (pH, DS) Temperature compensation: NTC10K/ NTC2.252K /PT100/PT1000
  • Pressure resistance: ≤0.4Mpa
  • Thread: PG13.5mm
  • Body material: Glass
  • Application: Pharmaceutical industry, food and beverage Processes, starch slurry, etc
Enquire Now

SR-PH-704 pH sensor parameter

  • Measuring range: 0~14pH
  • Temperature range: 0~80°C
  • (ORP) Zero electric potentia (pH, DS) Temperature compensation: Optional
  • Pressure resistance: 100PSI
  • Thread: 3/4NPT
  • Body material: FRPP
  • Application: Farming, municipalities environmental protection, Water treatment
Enquire Now

SR-PH-701 pH sensor parameter

  • Measuring range: 0~14pH
  • Temperature range: 0~80°C
  • (ORP) Zero electric potentia (pH, DS) Temperature compensation: Optional
  • Pressure resistance: ≤0.4Mpa
  • Thread: 3/4NPT
  • Body material: PPS
  • Application: Mining and smelting, Wastewater treatment
Enquire Now

SR-PH-513A pH sensor parameter

  • Measuring range: 0~14pH
  • Temperature range: 0~60°C
  • (ORP) Zero electric potentia (pH, DS) Temperature compensation: NTC10K/PT1000
  • Pressure resistance: ≤0.3Mpa
  • Thread: 3/4NPT
  • Body material: PTFE
  • Application: Heavy polluted water strong acid and alkali working conditions
Enquire Now

SR-PH-703 pH sensor parameter

  • Measuring range: 2~12pH
  • Temperature range: 5~80°C
  • (ORP) Zero electric potentia (pH, DS) Temperature compensation: NTC10K, PT100, PT1000
  • Pressure resistance: ≤0.6Mpa
  • Thread: 3/4NPT
  • Body material: PPS
  • Application: Wastewater treatment, exhaust gas treatment
Enquire Now

SR-ORP-641 ORP sensor parameter

  • Measuring range: ±1999mV
  • Temperature range: 5~60°C
  • (ORP) Zero electric potentia (pH, DS) Temperature compensation: 245~270mV
  • Pressure resistance: ≤0.4Mpa
  • Thread: PG13.5mm
  • Body material: Glass
  • Application: Industrial Wastewater, acid and alkali neutralization
Enquire Now

SR-ORP-650 ORP sensor parameter

  • Measuring range: -2000~2000m0
  • Temperature range: 0~80°C
  • (ORP) Zero electric potentia (pH, DS) Temperature compensation: 245~270mV(15~30℃ Measuring 256mV calibration solution)
  • Pressure resistance: ≤0.6Mpa
  • Thread: 3/4NPT
  • Body material: PPS
  • Application: Industrial Wastewater, With suspended matter in solution, such as aquaculture, mining
Enquire Now

SR-TDS-701 EC sensor parameter

  • Measuring range: 0.01~20,0.1~200 1~2000μs/cm (optional)
  • Temperature range: 0~50°C
  • (ORP) Zero electric potentia (pH, DS) Temperature compensation: Optional
  • Pressure resistance: ≤5Mpa(Electrode constant 0.01,0.1) | ≤7Mpa(Electrode constant 1.0)
  • Thread: G3/4,3/4NPT(optional)
  • Body material: SUS304 | SUS316
  • Application: Tap water
Enquire Now

SR-TDS-703 EC sensor parameter

  • Measuring range: 0.1us/cm~70ms/cm
  • Temperature range: 0~80°C
  • (ORP) Zero electric potentia (pH, DS) Temperature compensation: Optional
  • Pressure resistance: ≤3Mpa
  • Thread: G3/4 (3/4NPT customizable)
  • Body material: PPS,POM,ABS
  • Application: Mining and smelting, Wastewater treatment
Enquire Now

SR-PH-801 Digital pH sensor

  • Measuring range: ±1000.0mV (0.00~14.00)pH
  • Temperature range: 0~60°C
  • Accuracy: 0.02pH /0.5°C /0.2mV
Enquire Now

SR-ORP- 801 Digital ORP sensor

  • Measuring range: ±1000.0mV
  • Temperature range: 0~60°C
  • Accuracy: 0.5°C/ 0.2mV
Enquire Now

SR-TDS-801 Digital EC sensor

  • Measuring range: Conductivity (0~9999)uS/cm (10.00~70.00)mS/cm|  TDS(0~9999)ppm | Salinity(0~40.00)ppt
  • Temperature range: 0~60°C
  • Accuracy: ±2.5%
Enquire Now

SR-TDS-802 Digital EC sensor

  • Measuring range: (0~500)mS/cm
  • Temperature range: 0~60°C
  • Accuracy: 1.5%FS
Enquire Now

SR-DO-718 Optical Do sensor

  • Measuring range: Dissolved oxygen (0~20)mg/L or saturation(0~200%) | Temperature(0~50)°C
  • Temperature range: 0~45℃(no freezing
  • Accuracy: Dissolved oxygen: ±0.3 mg/L Temperature:±0.2°C
Enquire Now

SR-DO-719 Optical Do sensor

  • Measuring range: Dissolved oxygen (0~20)mg/L or saturation(0~200%) | Temperature(0~50)°C
  • Temperature range: 0~45℃(no freezing
  • Accuracy: Dissolved oxygen: ±3% or ±0.3 mg/L | Temperature:±0.5°C
Enquire Now

SR-PSS-911 SS/TSS sensor

  • Measuring range: (0.01~20000)mg/L (0.01~45000)mg/L (0.01-120000)mg/L
  • Temperature range: 0~45℃(no freezing
  • Accuracy: Less than ±5% (depending on sludge homogeneity)
Enquire Now

SR-PTU-811 Turbidity sensor

  • Measuring range: (0.01~4000)NTU
  • Temperature range: 0~45℃(no freezing
  • Accuracy: Less than ±2% of the measured value or ±0.1NTU